APOJET Technical data - Specifications

Type

APOJET R 20

APOJET R 40

APOJET R 90

APOJET R 120

Input:

 

 

 

 

Voltage, 3 ph

V

400 + 10%

 

 

Frequency

Hz

50

 

 

Rated Current /A

36

64

136

178

Appox. Starting current/A

60

150

130

178

Approx. starting time/s

15

10

35

35

Speed:

 

 

 

 

no-load/full load

rpm

3000/2970

 

 

 

 

 

 

 

Output:

 

 

 

 

Rated Power

KVA

20

40

 90

Power factor

cos phi 0.8

 

 

 

Voltage, 3 ph

V

200/11 5

 

 

Frequency:

 

 

 

 

No-load/full load

Hz

400/398

 

 

Rated Current

 58

116

260

346

Static Voltage deviation %

+ 1 with balanced load

 

 

Dynamic voltage deviation

% acc. to MlL-Std 704. fig 5

Voltage adjustment range %

+ 10 of rated voltage

 

 

Distortion factor ph-ph

% < 1 with balanced, linear load

 

 

 

 

 

 

General data:

 

 

 

 

Max. installation altitude m

1000 above mean sea-level

 

 

Permissible ambient temp

C O to 40

 

 

 

Max. relative humidity

% 95

 

 

 

Approx power dissipation/ kW

4.3

9

10

12.5

Approx. weight/ kg

640

880

1270

1300

Paint finish

FAL 7032

 

 

 

Protection type

IP 43 or IP 54

 

 

 

 

 

 

 

 

INDOOR/IP43

 

 

 

 

Dimensions 1) mm

1675 x 800 x 1100

 

 

WxDxH 2) mm

1900x800x1100

 

 

Noise level 1)

dB(A) 88

71

76

76

2)

dB(A) 65

69

72

72

1) as depicted

 

 

 

 

2) with cowls at air in-/outlet

 

 

 

 

Piller GmbH is constantly improving products. We reserve the right to change design and or specifications without notice