Preliminary Issue

TADIRAN LITHIUM BATTERIES - NEW PULSES PLUS

For High Pulse-Current Applications

NEW for OCEANOGRAPHIC APPLICATIONS


Any representations in these data sheets concerning performance are for information purposes only and not warranties, either expressed or implied, of future performance. Sept. 2000


Model: TLP-97311/A/S - Up to 2A Pulse Capability

Nominal capacity to 2.0V

1.65Ah

Capacity to 3.0V (@ 250mA @ 1% duty cycle)

1.60Ah

Open circuit voltage

3.67V

Maximum 1 second pulse to 3.0V

1A

Maximum pulse length (@ 125mA to 3.0Volts)

200 sec.

Delay time to 3.0V (@ 125mA after 1 year)

<1 msec.

Diameter (max.)

17.2 mm

Length (max.)

56.3 mm

Weight (max.)

25 gr.

Capacity retention after 10 years

85%

Operating life (@ 14μA continuous current)

10 Years

Operating temperature

-40°C to +85°C

Available Terminations:

.

TLP-97311/A/S Standard Cat. No. 61973111100

.

TLP-97311/A/T Solder Tabs Cat. No. 61973111700

.

Click to view 97311 Performance Graphs

 

<<BACK

Model : TLP-97111/A/S - Up to 5A Pulse Capability

Nominal capacity to 2.0V

1.65Ah

Capacity to 3.0V (@ 250mA @ 1% duty cycle)

1.60Ah

Open circuit voltage

3.67V

Maximum 1 second pulse to 3.0V

3A

Maximum pulse length (@ 125mA to 3.0 Volts)

200 sec.

Delay time to 3.0V (@ 125mA after 1 year)

<1 msec.

Capacity retention after 10 years

85%

Operating life (@12μA continuous current)

10 Years

Operating temperature

-40°C to +85°C

Available Terminations:

.

TLP-97111/A/S Standard Cat. No. 61971111400

.

Click to view 97111 Performance Graphs

<<BACK

Model: TLP-96311/A/S - Up to 2A Pulse Capability

Nominal capacity to 2.0V

1.2Ah

Capacity to 3.0V (@ 250mA @ 1% duty cycle)

1.1Ah

Open circuit voltage

3.67V

Maximum 1 second pulse to 3.0V

1A

Maximum pulse length (@ 125mA to 3.0 Volts)

200 sec.

Delay time to 3.0V (@ 125mA after 1 year)

<1 msec

Diameter (max.)

17.2 mm

Length (max.)

48.1 mm

Weight

23 gr.

Capacity retention after 10 years

85%

Operating life (@10μA continuous current)

10 Years

Operating temperature

-40°C to +85°C

Available Terminations:

.

TLP-96311/A/S Standard Cat No. 61963111100

.

TLP-96311/A/T Solder Tabs Cat. No. 61963111700

.

Click to view 96311 Performance Graphs

<<BACK

Model: TLP-96111/A/S - Up to 5A Pulse Capability

Nominal capacity to 2.0V

1.2Ah

Capacity to 3.0V (@ 250 mA @ 1% duty cycle)

1.1Ah

Open circuit voltage

3.67V

Maximum 1 second pulse to 3.0V

3A

Maximum pulse length (@ 125 mA to 3.0 Volts)

200 sec.

Delay time to 3.0V (@ 125 mA after 1 year)

<1 msec.

Capacity retention after 10 years

85%

Operating life (@ 8μA continuous current)

10 Years

Operating temperature

-40°C to +85°C

Available Terminations:

.

TLP-96111/A/S Standard Cat No. 61961111400

.

Click to view 96111 Performance Graphs

 

<<BACK

Model: TLP-93311/A/S - Up to 2A Pulse Capability

Nominal capacity to 2.0V

19.0 Ah

Capacity to 3.0V (@ 250 mA @ 1% duty cycle)

19.0 Ah

Open circuit voltage

3.67V

Maximum 1 second pulse to 3.0V

1A

Maximum pulse length (@ 125 mA to 3.0 Volts)

200 sec.

Delay time to 3.0V (@ 125 mA after 1 year)

<1 msec.

Diameter (max.)

35.2 mm

Length (max.)

80.2 mm

Weight

126 gr

Capacity retention after 10 years

85%

Operating life (@ 190μA continuous current)

10 Years

Operating temperature

-40°C to +85°C

Available Terminations:

 

TLP-93311/A/S Standard Cat.No.61933111100

 

TLP-93311/A/T Solder Tabs Cat. No. 61933111700

 

Click to view 93311 Performance Graphs

 

<<BACK

Model : TLP-93111/A/S - Up to 5A Pulse Capability

Nominal capacity to 2.0V

19.0 Ah

Capacity to 3.0V (@250mA @ 1% duty cycle)

19.0Ah

Open circuit voltage

3.67V

Maximum 1 second pulse to 3.0V

3A

Maximum pulse length (@ 125 mA to 3.0 Volts)

200 sec.

Delay time to 3.0V (@ 125 mA after 1 year)

<1 msec.

Capacity retention after 10 years

85%

Operating life (@190μA continuous current)

10 Years

Operating temperature

-40°C to +85°C

Available Terminations:

 

TLP-93111/A/S Standard Cat. No. 61311111400

 

Click to view 93111 Performance Graphs

 

<<BACK

Model TLP-92311/A/S - Up to 2A Pulse Capability

Nominal capacity to 2.0V

8.50Ah

Capacity to 3.0V (@ 250 mA @ 1% duty cycle)

8.50Ah

Open circuit voltage

3.67V

Maximum 1 second pulse to 3.0V

1A

Maximum pulse length (@ 125mA to 3.0 Volts)

200 sec.

Delay time to 3.0V (@ 125mA after 1 year)

<1 msec.

Diameter (max.)

28.2 mm

Length (max.)

69.5 mm

Weight (max.)

75 gr.

Capacity retention after 10 years

85%

Operating life (@ 80μA continuous current)

10 Years

Operating temperature

-40°C to +85°C

Available Terminations:

.

TLP-92311/A/S Standard Cat. No 61923111100

.

TLP-92311/A/T Solder Tabs Cat No 61923111700

.

Click to view 92311 Performance Graphs

 

<<BACK

Model : TLP-92111/A/S - Up to 5A Pulse Capability

Nominal capacity to 2.0V

8.50Ah

Capacity to 3.0V (@ 250 mA @ 1% duty cycle)

8.50Ah

Open circuit voltage

3.67V

Maximum 1 second pulse to 3.0V

3A

Maximum pulse length (@125 mA to 3.0 Volts)

200 sec.

Delay time to 3.0V (@ 125 mA after 1 year)

<1 msec.

Capacity retention after 10 years

85%

Operating life (@ 80μA continuous current)

10 Years

Operating temperature

-40°C to +85°C

Available Terminations:

.

TLP-92111/A/S Standard Cat. No. 61921111400

.

Click to view 92111 Performance Graphs

 

<<BACK

Model: TLP-91311/A/S - Up to 2A Pulse Capability

Nominal capacity to 2.0V

2.50 Ah

Capacity to 3.0V (@ 250 mA @ 1% duty cycle)

2.40 Ah

Open circuit voltage

3.67V

Maximum 1 second pulse to 3.0V

1A

Maximum pulse length (@ 125mA to 3.0 Volts)

200 sec.

Delay time to 3.0V (@ 125 mA after 1 year)

<1 msec.

Diameter (max.)

17.2 mm

Length (max.)

73.0 mm

Weight

33 gr.

Capacity retention after 10 years

85%

Operating life (@ 22μA continuous current)

10 Years

Operating temperature

-40°C to +85°C

Available Terminations:

.

TLP-91311/A/S Standard Cat. No. 61913111100

.

TLP-91311/A/T Solder Tabs Cat No 61913111700

.

Click to view 91311 Performance Graphs

 

<<BACK

Model: TLP-91111/A/S - Up to 5A Pulse Capability

Nominal capacity to 2.0V

2.50 Ah

Capacity to 3.0V (@ 250 mA @ 1% duty cycle)

2.40 Ah

Open circuit voltage

3.67V

Maximum 1 second pulse to 3.0V

3A

Maximum pulse length (@125 mA to 3.0 Volts)

200 sec.

Delay time to 3.0V (@ 125 mA after 1 year)

<1 msec.

Capacity retention after 10 years

85%

Operating life (@ 20μA continuous current)

10 Years

Operating temperature

-40°C to +85°C

Available Terminations:

.

TLP-91111/A/S Standard Cat. No. 61911111400

.

Click to view 91111 Performance Graphs

 

<<BACK

NEW OCEANOGRAPHIC APPLICATIONS Model: TLP-93181/D/OCN2

Nominal capacity to 12.0V (@ 3A & 1% duty cycle)

152 Ah

Open circuit voltage

14.68V

Maximum 1 second pulse to 12.0V

3A

Delay time to 12.0V (@ 400 mA after 1 year)

<1 msec.

Capacity retention after 10 years

85%

Weight

3250gr

Operating temperature

- 40°C to +60°C

TLP-93181/D/OCN2 Ordering Cat. No. 61931811100

.

Click to view 93181/D/OCN2 Performance Graphs

 

<<BACK